    Interface Ten-GigabitEthernet1/0/11: Operational status 和 Interface Ten-GigabitEthernet1/0/11(Ten-GigabitEthernet1/0/11 Interface): Duplex status 的区别是啥呀,为啥 Interface Ten-GigabitEthernet1/0/11: Operational status 有时候会取不到值,有时候就取得到呢
    5 replies    2024-06-12 13:18:04 +08:00
    bigmomo
        1
    bigmomo  
       Jun 12, 2024
    Operational status 是手动操作状态,代表是否人工 down ,Duplex status 是双工模式。
    echoo00
        2
    echoo00  
       Jun 12, 2024
    Interface Ten-GigabitEthernet1/0/11: Operational status 是接口的状态一般是 UP 或者 DOWN ,
    Interface Ten-GigabitEthernet1/0/11(Ten-GigabitEthernet1/0/11 Interface): Duplex status 这个是接口的双工模式,一般是 fullDuplex/ halfDuplex ,
    取不到值的问题我的猜测是这个接口是不是虚拟接口,物理接口中我没遇到过取不到值的问题
    nullo
        3
    nullo  
    OP
       Jun 12, 2024
    @echoo00 师傅,Operational status 是 1 代表 up ,2 代表 down 的话,那么取值到 1.3 、1.7 这种代表啥情况呀,主要想用来做 grafana 的展示
    wheat0r
        4
    wheat0r  
       Jun 12, 2024
    @nullo #3 zabbix 没用过。
    原则上是不应该有非整数值的,这是不是应该看网络设备厂家的 mib oid 说明?
    或者是不是 oid 可以多加一位.1 就可以取到后面的整数值?
    思科的 OID 定义是“1-up, 2-down, 3-testing, 4-unknown, 5-dormant, 6-notPresent, 7-lowerLayerDown”
    echoo00
        5
    echoo00  
       Jun 12, 2024
    我也没有取到过小数的值,这个得参考你设备的 MIB 库的说明了